GENEL CİHAZ ve SARFLAR
Stuart Erime Noktasi Tayin Cihazi, Melting Point Apparatus, Analog, SMP11
Easy to operate - ideal for educational use
Supplied with safe spirit filled thermometer
Economical price
With new safety features and easy to use, the SMP11 is ideal for use
in education.
Supplied with a safe, spirit filled mercury free thermometer, the
low toxic blue spirit will not pose a health hazard in the event of
a breakage. Easy to follow instructions are printed directly on to
the apparatus and are available in most European languages.
With a manually adjustable heating rate, the SMP11 will rapidly heat
samples up to 20°C per minute to the melt temperature and up to the
maximum temperature of 250°C. Accurate readings to within 1°C of the
melt temperature can be achieved by using a slower heating rate of
between 1 and 10°C per minute.
Up to three samples can be viewed and tested at any one time.
Samples are illuminated by a bright white LED and viewed via a
magnifying lens. The magnifying lens can be detached for cleaning
using the simple to follow instructions printed on to the
instrument.
No. of samples
Up to 3
Temperature range
Ambient to 250°C
Heating rate
1 to 10 °C/min
Dimensions (w x d x h)
370 x 140 x 110 mm
Net weight
1.7kg
Electrical supply
230V, 50Hz, 50W
Electrical supply 230V, 50Hz, 50W
Melting point tubes
Made from soda glass, these tubes are easy to seal in a Bunsen flame
and break into two. Supplied in robust tube holder, pack of 100
tubes. Tube overall length is 100mm Tube diameter = 1.9mm, inner
diameter = 1.3mm and wall thickness = 0.3mm
SMP11 Melting point
Apparatus, complete with thermometer and pack of 100 melting point
tubes (open both ends)
SMP11/1 Spare thermometer, spirit filled,
0°C to 250°C
SMP1/2 Cooling plug (brass) for
rapidly reducing heating block temperature after use
SMP1/4 Glass melting point
tubes, open at both ends, pack of 100
SMP2/1 Glass melting point
tubes, closed at both ends, pack of 100
SMP10/1 Glass melting point tubes, closed at
one end, pack of 100
Stuart Erime Noktası Tayin Cihazı, Melting Point Apparatus, Analog, SMP10
Digital
selection & display of temperature
High accuracy
Easy to operate with plateau facility
Ideal for educational use
Supplied with calibration certificate
The SMP10 has been designed with safety and ease of operation in
mind making it ideal for use in education. The temperature is
selected, measured and displayed digitally making it accurate and
negating the need for a thermometer.
Two samples can be tested simultaneously. They are viewed via a
magnifying lens with clear observation aided by built in
illumination. Extendible back feet allow the unit to be operated at
the optimum viewing angle. Full access to the block aids cleaning.
The simple to follow instructions are printed directly on the
instrument in most European languages for ease of use.
To operate simply select a plateau temperature via the three digit
display and press "start". The unit quickly heats up and remains at
the selected plateau temperature until the user is ready to start
the test. Insert the sample tubes and press "start". The unit then
heats slowly so that the melt can be observed. When the sample is
seen to melt, note the temperature on the display. Press "stop" to
end heating and cool the block.
Supplied complete with calibration certificate showing individual
serial number for traceability.
Number of samples
2
Temperature range
Ambient to 300°C
Temperature accuracy
± 1.0°C at 20°C, ± 2.5°C at 300°C
Display
Three digit LED
Display resolution
1°C
Sensor
Platinum resistance PT100
Ramp rates
20°C per minute to plateau, 2°C per minute to melt
Dimensions (w x d x h)
160 x 220 x 170mm
Net weight
1.8 Kg
Electrical supply
230V, 50Hz, 75W
Melting point tubes
Made from soda glass, these tubes are easy to seal in a Bunsen flame
and break into two. Supplied in robust tube holder, pack of 100
tubes. Tube overall length is 100mm Tube diameter = 1.9mm, inner
diameter = 1.3mm and wall thickness = 0.3mm.
SMP10 Melting point
apparatus, complete with pack of 100 melting point tubes, closed at
one end
SMP10/1 Glass melting point
tubes, closed at one end, pack of 100
SMP2/1 Glass melting
point tubes, closed at both ends, pack of 100
SMP1/4 Glass melting
point tubes, open at both ends, pack of 100
Stuart Erime Noktası Tayin Cihazı, Melting Point, Gelişmiş Dijital, SMP30
Maximum
temperature 400°C
Patented head up display
Integrated cooling 350°C to 50°C in 10 minutes
Large easy to read user friendly interface
Designed for fast accurate determination of melting points, the
SMP30 can take three samples simultaneously within the optimised
heating block, the unit has a maximum temperature of 400°C. To allow
maximum flexibility a plateau facility is included with variable
ramp rate between 0.5 and 10°C in 0.1°C increments. The tubes are
illuminated with bright white LED's to give the clearest view of the
samples during the melt. The block has been designed for easy access
for cleaning, the front of the head is fully removable to allow full
access to the micro furnace.
The SMP30 has a large clear back lit alphanumeric LCD display,
running the menu system which clearly guides you through the melting
process with comprehensive directions. Language is switchable
between English, German, French and Italian. It is possible to
record up to 8 events in memory for each of the three sample tubes,
as well as being temperature stamped these events are also date and
time recorded, thanks to the integrated real time clock.
The SMP30 features the patent pending head up display, this unique
feature displays a floating image of the block temperature, visible
through the eyepiece, in front of the tubes. The head up display
eliminates the need for the user to keep switching their gaze
between the tubes and the temperature display, through the eyepiece
they can now see both at once.
To allow the most comfortable viewing angle the SMP30 features a two
stage head adjustment, in the first movement the head is pulled
towards the user, then in a separate motion the angle of the head
can be adjusted by up to 126°, and will automatically hold in place
due to the torsion resistant design to create the perfect viewing
angle. The head can then be stored safely back within the body of
the unit for storage.
The design of the unit has lots of other useful features such as
slots for storing pre-prepared samples and a storage draw to hold a
container of capillary tubes.
An accessory printer is available separately to produce a written
record of the melt, and all units are supplied with a calibration
certificate showing individual serial numbers for traceability.
No of samples
3
Temperature range
Ambient to 400°C
Temperature resolution
0.1°C
Temperature accuracy
±0.5 at 50°C, ±1.0 at 100°C, ±2.5 at 360°C
Display
40 x 4 LCD
Ramp rates
0.5-10°C in 0.1°C increments
Temperature sensor
PT1000 Platinum resistance
Memory
8 results per tube
Accessory printer available
Yes
Date/time display
Yes
Cool down time 350-50°C
~10 mins
Heat up time 50-350°C
~ 6 mins
Electrical supply
120V/230V, 50Hz
Language variants
English, German, French, Italian
Temperature units
°C
Size (h x d x w)
325 x 200 x 170mm
Net Weight
3.6kg
SMP30
Melting point apparatus, complete with pack of 100 melting point
tubes, open at one end.
SMP30/1
Accessory printer with power supply
SMP10/1
Glass melting point tubes, closed at one end, pack of 100
Stuart Otomatik Erime Noktası Tayin Cihazı, Automatic Melting Point, SMP40
Maximum temperature 400°C
Utilises latest technology in digital imaging
5.7 Inch colour VGA touch screen display
Unique split design concept
Integrated cooling 350°C to 50°C in 10 minutes
Also available with IQ/OQ documentation
The SMP40 automatic melting point uses the latest technology in
digital image processing to accurately identify the melt of up to
three samples simultaneously. The unit comes with a 5.7 inch colour
VGA display, on which the melt can be watched real time, or the melt
video will automatically be saved as an AVI file that can be
reviewed later, either on the unit or via PC, providing traceability
long after the sample has gone. The result can also be overridden if
for any reason you dont agree with the result calculated by the
image processing algorithm.
The SMP40 is fully programmable via the touch screen display, once
the user has set the plateau temperature up to the maximum
temperature of 400°C they can select the ramp rate, between 0.1 and
10°C in 0.1°C increments. During use a library of preset methods can
be built up to streamline the method input for repeat measurements.
For materials where the user is unaware of an approximate melting
point, and therefore unable to set the plateau temperature, the
SMP30 can be used in rapid melt mode. During rapid melt mode a fast
scan of the full temperature range is undertaken to provide an
approximate melt temperature, then a method will be automatically
programmed with the appropriate plateau temperature to allow a more
accurate measurement to be carried out.
The SMP40 has an innovative split design concept, the unit can be
used as normal or the control side and the melt side can be
separated, allowing for the maximum in footprint flexibility. After
the samples have been loaded the melt side of the unit can be placed
at the back of the bench or even in a fume cupboard to catch any
potentially dangerous fumes. Once the unit has been split the
control panel side can be used in two orientations, either landscape
or portrait to allow the perfect viewing angle whether you are sat
or stood at the bench, the screen automatically changes orientation
with the unit.
The unit can store up to 200 result files with videos, if required
data can be easily transferred from the unit to a flash memory drive
or PC via one of the USB connectors.
The unit has been designed to include a number of other useful
features such as slots to accommodate pre-prepared samples and a
draw to house your unused melting point tubes. Also included in the
draw is a handy glass cutter, which can be used to accurately cut
tubes in half quickly and cleanly for users who prefer to use half
tubes.
All units are supplied with a calibration certificate showing
individual serial numbers for traceability. The SMP40 conforms to
Pharmacopeia and GLP.
No of samples
3 simultaneously
Temperature range
Ambient to 400°C
Temperature resolution
0.1°C
Display
5.7
Ramp rates
0.1-10°C in 0.1°C increments
Temperature sensor
PT1000 Platinum resistance
Memory
200 results with video
Cool down time 350-50°C
~10 mins
Heat up time 50-350°C
~ 6 mins
Oven control
Closed loop PID
Flash memory/PC interface
USB
Sample level
2-3mm in 50mm or 100mm length capillaries
Electrical supply
120V / 230V, 50Hz
Temperature units
°C, °F, K
Size (h x d x w)
175 x 210 x 328mm
Net Weight
3.2kg
Languages
English, French
SMP40
Automatic melting point apparatus, complete with pack of 100 melting
point tubes, closed at both ends.
SMP40/IQOQ Automatic
melting point apparatus, complete with IQ/OQ documentation and pack
of 100 melting point tubes, closed at both ends.
SMP2/1
Glass melting point tubes, closed at both ends, pack of 100